![Daher TBM 900 Скачать руководство пользователя страница 270](http://html.mh-extra.com/html/daher/tbm-900/tbm-900_pilots-information-manual_499727270.webp)
Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 4.4.31
Motoring followed by an engine start
2/3
►
Continuing
13 -
Motor
For 30 sec. max
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
After 20 seconds and if ITT < 150°C :
14 -
IGNITION switch
AUTO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 -
Ng
Check
>
13 %
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 -
THROTTLE
LO-IDLE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitor increase of :
17 -
ITT
max. : < 870°C for 20 sec max.
. . . . . . . . . . . . . . . . . . . . . . .
< 1000°C for 5 sec max.
●
NOTE
●
No action is required for the following conditions :
- ITT from 850°C to 870°C limited to 20 seconds,
- ITT from 870°C to 1000°C limited to 5 seconds
●
18 -
Ng
19 -
Oil pressure
20 -
OIL PRESS
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When Ng > 50 % :
▲
CAUTION
▲
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
▲
21 -
Starter
Check OFF automatically
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 -
STARTER
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 -
Engine parameters
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 %
≤
Ng
≤
58 %, oil pressure and ITT in green sector
Continue
►
PIM - DO NOT USE FOR FLIGHT OPERATIONS