Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 3.9.1
3.9
- Electrical system
ESI-2000 failures
1/2
Battery indicator symbol meaning
Battery
indicator
Description
Not shown
Normal operation - No information needs to be conveyed
Green
More than one hour of operation remains
Amber
Less than one hour of operation remains
Amber ”X”
Battery is not available to power unit : overtemperature
or low battery voltage condition exists
Red ”X”
Battery has failed - Service is required
ESI-2000 attitude invalid in flight :
1 -
Maintain straight and level flight at a constant airspeed.
2 -
M button
Press twice
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -
S button
Press once
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The ESI-2000 will initiate the alignment process.
When a normal attitude display is available :
4 -
Resume normal flight.
If attitude information remains invalid :
5 -
Use attitude information from the primary attitude display.
End of procedure
■
Red X’d battery symbol displayed in flight :
Indicates internal battery failure.
1 -
Remain clear of IMC.
Continue
►