![Daher TBM 900 Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/daher/tbm-900/tbm-900_pilots-information-manual_499727113.webp)
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 5
Page 3.4.3
Air start procedures
2/2
►
Continuing
When Ng > 50 % :
14 -
Starter
Check OFF automatically
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If starter has not turned off automatically :
15 -
STARTER switch
ABORT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 -
THROTTLE
Flight IDLE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 -
THROTTLE
As required
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 -
BLEED switch
As required
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 -
AUX BP switch
AUTO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 -
Electrical equipment
As required
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If necessary :
21 -
Perform procedure
Emergency descent
. . . . . . . . . . . . . . . . . . . . . . . . .
Refer to chapter 3.6
If air start is not successful :
22 -
Perform procedure
Forced landing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refer to chapter 3.7
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS