![Daher TBM 900 Скачать руководство пользователя страница 265](http://html.mh-extra.com/html/daher/tbm-900/tbm-900_pilots-information-manual_499727265.webp)
Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 4.4.26
Engine start
3/3
►
Continuing
When
-
Ng > 50 % and,
-
1 minute max :
▲
CAUTION
▲
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
▲
16 -
Starter
Check OFF automatically
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 -
STARTER
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 -
Engine parameters
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 %
≤
Ng
≤
58 %, oil pressure and ITT in green sector
End of procedure.