xStack Gigabit Layer 3 Switch Command Line Interface Manual
Example usage:
To view the SSL cache timeout on the Switch:
DGS-3324SRi:4#show ssl cachetimeout
Command: show ssl cachetimeout
DGS-3324SRi:4#
Cache timeout is 600 second(s).
show ssl
Purpose
Used to view the SSL status and the certificate file status on the
Switch.
Syntax
show ssl {certificate}
Description
This command is used to view the SSL status on the Switch. Adding
the certificate parameter will allow the user to view the certificate file
information currently set on the Switch.
Parameters
{certificate} –
Adding this parameter will allow the user to view
certificate file information currently implemented on the Switch.
Restrictions None.
Example usage:
To view the SSL status on the Switch:
DGS-3324SRi:4#show ssl
RSA_WITH_3DES_EDE_CBC_SHA 0x000A Enabled
Command: show ssl
SSL status Disabled
RSA_WITH_RC4_128_MD5 0x0004 Enabled
DHE_DSS_WITH_3DES_EDE_CBC_SHA 0x0013 Enabled
RSA_EXPORT_WITH_RC4_40_MD5 0x0003 Enabled
DGS-3324SRi:4#
Example usage:
To view certificate file information on the Switch:
DGS-3324SRi:4# show ssl certificate
Command: show ssl certificate
Loaded with RSA Certificate!
DGS-3324SRi:4#