Module Appearance
Figure 1-33 Appearance of the RG-WALL 1600-B-U
External Interface
The RG-WALL 1600-B-U module provides two external interfaces:
Console port: As the serial communications port, it uses RS-232 interface level and standard RJ-45 connector. This
port is used to connect the serial port of terminal computers running on the background for tasks such as firewall
debugging, configuration, maintenance, management, and host software loading.
10/100M MGMT port: As the 10/100BASE-T Ethernet port, it uses RJ-45 connector. This port can be used to connect
the Ethernet port of the background computer for loading programs.
LED
Sign
Description
Detailed information
Status
System LED
OFF: The module is not powered on.
Red: The module is faulty.
Blinking green: The module is initializing. If it keeps blinking, the
module may be faulty.
Solid green: The module has finished initialization and can perform
switching well.
10/100M MGMT
Port LED
Link/ACT
OFF: The port link is not up.
Green: The port link is up at 100 Mbps.
Yellow: The port link is up at 10 Mbps.
Blinking: The port is transceiving data.
Specifications
Model
RG-WALL 1600-B-U
Standard
Compliance
IEEE 802.3-2005 Ethernet Standard
Port Type
One console port for management, one 10/100M MGMT port, no switching port
Transmission
Medium
N/A
LED
Status, Link/ACT
Hot Swapping
Supported
Power
Consumption
<90W
EMC Standards
GB9254-2008
Safety Standards
GB4943-2011
Operating
Temperature
0 to 40°C
Storage
Temperature
-40 to 70°C
Operating
Humidity
10% to 90% RH (non-condensing)
Weight
Net weight: 3.2 kg
Dimensions
(L x W x H)
436 mm x 346 mm x 45 mm
RG-WALL 1600 FW Module
The RG-WALL 1600 FW is a service card that supports the firewall function and can expand the firewall function of the
S8600 switches.
Module Appearance
Figure 1-34 Appearance of the RG-WALL 1600 FW Module
Содержание RG-S8606 B
Страница 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Страница 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Страница 62: ...Figure 2 6 Ventilation of RG S8614 ...
Страница 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Страница 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Страница 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Страница 116: ......