LED
The M8610/ M8606-FAN B module provides LEDs indicating various system status, as described in the following table:
Sign
Description
Detailed information
Power
Power LED
OFF: The fan tray is not powered on.
Solid green: The fan tray is normally powered on.
Alarm
Alarm LED
OFF: The fan tray is working normally.
Red: The fan tray is faulty.
In the RG-S8614/S8610/S8606/S8606 B system, an alarm on the fan tray M8614/M8610/M8606-FAN/M8606-FAN B
indicates that the fan tray has failed. In this case, you need to replace the failed one with a normal one as quickly as
possible.
The M8614/M8610/M8606-FAN/M8606-FAN B fan tray is hot swappable.
Specifications
Fan model
M8614-FAN
M8610-FAN
M8606-FAN
M8606-FAN B
Ventilation
118CFM x 10
118CFM x 6
118CFM x 6
174CFM x 4
Power Consumption
120W
60W
60W
150W
Weight
5.825 kg
4.29 kg
5.46 kg
3 kg
Dimensions
(W x H x D)
286.4 mm x 690.2
mm x 75.7 mm
432 mm x 66 mm x
374 mm
432.4 mm x 405.4
mm x 46.8 mm
310 mm x 257 mm x
64.4 mm
The depth of the M8614/M8606 fan module excludes the depth of the handle and captive screw.
RG-PA1200/PA1200E/PA1200I/PA2000I/PA2000/PA800IF
The AC power module RG-PA1200/PA1200E/PA1200I/PA2000I/PA2000 provides 110/220V AC power input module for
the RG-S8614/S8610/S8606. The AC power module RG-PA800IF provides 110/220V AC power input interface for the
RG-S8606B.
LED
RG-PA1200/PA1200E/PA1200I/PA2000I/PA2000 Module
Sign
Status
Details
IN
Off
No power input.
Solid green
Power input is operational.
OUT
Off
No power output.
Solid green
Power output is operational.
FAIL
Off
The power supply is operational.
Solid red
The power supply fails.
RG-PA800IF Module
Sign
Description
Details
Run
Power running LED
Green on indicates the power supply works normally. When
the “Fault” LED is red, or the “Alarm” LED is yellow not due to
over current
, this "Run” LED goes off.
Alarm
Power alarm LED
Yellow on indicates the recoverable fault such as AC
overvoltage/under voltage protection, over current protection,
over-temperature protection or ps-off module shutdown
occurs on the power supply.
Fault
Power fault LED
Red on indicates the recoverable fault such as fan fault,
external short circuit, output overvoltage or the recoverable
fault occurs. That is, when the “Alarm” LED is yellow, the
“Fault” LED must be red.
According to the description of LEDs of the RG-PA800IF module, when the AC power supply input is connected or
the power supply switch is off, AC under voltage
occurs due to no AC input, thus the “Alarm” LED is yellow, and the
“Fault” LED is red. And as long as the “Alarm” LED is yellow, the “Fault” LED is red. However, when the “Fault” LED
is red, the “Alarm” LED is not necessarily yellow.
Specifications
Содержание RG-S8606 B
Страница 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Страница 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Страница 62: ...Figure 2 6 Ventilation of RG S8614 ...
Страница 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Страница 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Страница 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Страница 116: ......