![D-Link RG-S8606 B Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/d-link/rg-s8606-b/rg-s8606-b_installation-and-reference-manual_78229036.webp)
The M8600-48GT/4SFP module provides four 10/100/1000BASE-T SFP combo ports. Each SFP port corresponds
to one combo 10/100/1000BASE-T port, and only one port can be used at a time, while the other is unavailable. The
automatic MDI/MDI-X identification of the 10/100/1000M copper ports takes effect only when auto-negotiation is
enabled.
The M8600P-48GT/4FP supports the PoE function, with a maximum of 15.4W of power output per port. If the host is
configured with the M8600P-48GT/4SFP line card, the power consumption should be calculated according to the
number of powered devices (PDs) attached and the power consumed by each PD.
The M8600P-48GT/4SFP supports hot swapping. You need to perform the following operations to achieve it:
1. Disconnect all cables connected to the PoE.
2. In the PoE mode, hold the
Mode
button for over three seconds until all LEDs on the line card go off.
3. Configure the pull-out operation through software commands. (For relevant software configuration commands,
refer to the corresponding software description.)
M8600-24SFP
Module Appearance
Figure 1-25 Appearance of the M8600-24SFP
External Interface
The M8600-24SFP provides 24 SFP ports that support the rate of 100/1000 Mbps and hot swapping.
LED
Sign
Description
Detailed information
Status
System LED
OFF: The module is not powered on.
Red: The module is faulty.
Blinking green: The module is initializing. If it keeps blinking, the module may be
faulty.
Solid green: The module has finished initialization and can perform switching well.
Link/ACT
Port status LED
OFF: The port link is not up.
Green: The 1000BASE-X port link is up.
Blinking green: The data is transmitted on the 1000BASE-X port.
Orange: The 100BASE-X port link is up.
Blinking orange: The data is transmitted on the 100BASE-X port.
Specifications
Model
M8600-24SFP
Standard Compliance
IEEE 802.3-2005 Ethernet Standard
Port Type
24 SFP 1000M/100M ports that support 1000BASE-X and100BASE-FX
Transmission Medium
1000BASE-SX(850nm)
Multi-mode optical fiber
1000BASE-LX(1310nm)
Single-mode optical fiber
1000BASE-LH40(1310nm)
Single-mode optical fiber
1000BASE-ZX(1550nm)
Single-mode optical fiber
100BASE-FX(1310nm)
Multi-mode or single-mode optical fiber
100BASE-FX(1550nm)
Single-mode optical fiber
LED
Status, Link/ACT LEDs
Hot Swapping
Supported
Power Consumption
<75W
EMC Standards
GB9254-2008
Safety Standards
GB4943-2011
Operating Temperature
0 to 40°C
Storage Temperature
-40 to 70°C
Operating Humidity
10% to 90% RH (non-condensing)
Weight
Net weight: 2.8 kg
Содержание RG-S8606 B
Страница 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Страница 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Страница 62: ...Figure 2 6 Ventilation of RG S8614 ...
Страница 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Страница 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Страница 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Страница 116: ......