The slots for the two management modules are in the middle and identified as M1 and M2 from bottom to top; the other
four line cards are numbered 1-4 from bottom to top.
Backplane
The RG-
S8606’s backplane interconnects high-speed data links from switch management board to module circuit board
and various management and control signals between modules. Its functions are as follows:
Interconnects all signals between modules and provide high-speed communication channel.
Passive backplane
Supports active/standby switching between management modules
Supports automatic identification of various slots
Implements distributed power supply
Introduces monitoring signal lines of the fan and power supply
Ventilation and Heat Dissipation System
The operating temperature of RG-S8606 is 0 to 40°C. The thermal design must ensure that the surface temperature of the
components does not exceed 50% to 80% of the allowed maximum temperature and satisfy the requirement on the
device’s reliability in the temperature range while ensuring the device’s reliability, safety and maintainability.. According to
the thermal design of RG-S8606, fans are used to draw air for forced convection cooling in order to ensure that the device
works properly in the specified environment.
Figure 1-6 Ventilation and Heat Dissipation System of the RG-S8606 Switch
This structure is designed with air inlet through the front plane, and air outlet at the back. The air flow direction is
shown above. Six 120 x 120 x 38 fans are used to blow air outside for convection and ultimately heat dissipation. The
chassis should be mounted in a place with sufficient space for air circulation. Sufficient space (10 cm at least) must
be reserved at the air intakes and exhaust vents for ventilation.
RG-S8606 B
The RG-8600 series is an A-class product and may cause radio disturbance to living environment. In this case, users
are advised to take proper measures against the disturbance.
Specifications
Model
RG-S8606 B
Module Slot
Six (two for management engine modules)
Содержание RG-S8606 B
Страница 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Страница 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Страница 62: ...Figure 2 6 Ventilation of RG S8614 ...
Страница 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Страница 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Страница 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Страница 116: ......