Connecting the External Interface Cables
Precautions
Correctly distinguish single-mode and multimode fibers and ports.
Avoid bends of small radius at the connector.
Simple Connection Steps
1)
Connect the RJ-45 end of the Ethernet cable to the Ethernet interface of the device board and the other end to the
NMS or a control terminal; or connect one end of the standard RJ-45 serial port cable to the serial port of the device
board and the other end to the NMS or a control terminal.
2)
Insert the single-mode or multimode fiber into the appropriate interface according to the identification on the panel of
the line card. Distinguish the Rx/Tx end of the fiber.
3)
Insert the twisted pair with the RJ-45 port into the appropriate interface according to the identification on the panel of
the line card. Distinguish the crossover cable and straight-through cable.
4)
Connect the cables and fibers of each board in sequence.
Binding the Cables
Precautions
The power cables and other cables should be bound in a visually pleasing way.
When you bind fibers, be sure that the fibers at the connectors have natural bends or bends of large radius.
Do not bind fibers and twisted pairs too tightly, as this may press the fibers and affect their longevity and transmission
performance.
Simple Binding Steps
1)
Bind the drooping part of the fibers and twisted pairs of each board, and lead them to both sides of the chassis for
convenience. For the RG-S8610, you can lead out the fibers and twisted pairs by using the cabling chute on the
chassis.
2)
On the both sides of the chassis, fasten the fibers or twisted pairs to the cabinet cable management ring or cabling
chute.
3)
For the power cables, you should bind them closely along the bottom of the chassis, in a straight line wherever
possible.
Installation Verification
Verifying the Cabinet
Verify if the external power supply matches the distribution panel of the cabinet.
After installing the equipment, verify if the front/back cabinet doors can be closed.
Verify that the cabinet has been fastened completely, and does not move or tilt.
Verify that the equipment has been installed in the cabinet, and all the cables have been fastened to the cabinet.
Verifying the Cables
Verify that the fibers and twisted pairs match the ports.
Verify that the cables have been bound properly.
Verifying the Power Supply
Verify that the power cables are in good contact and comply with the safety requirements.
Verify that the power module has been fastened onto the equipment with the two screws on the panel.
Turn on the power switch and verify that the power module can work normally.
Содержание RG-S8606 B
Страница 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Страница 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Страница 62: ...Figure 2 6 Ventilation of RG S8614 ...
Страница 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Страница 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Страница 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Страница 116: ......