DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
610
66-11 subnet-base (vlan)
This command is used to specify subnet-based VLAN ID assignment entry for un-tagged incoming packets. Use the
no
subnet-base
command to remove a subnet-based VLAN ID assignment entry.
subnet-base {
NETWORK-PREFIX /PREFIX-LENGTH
|
IPV6-NETWORK-PREFIX /PREFIX-LENGTH
} [priority
COS-VALUE
]
no subnet-base {
NETWORK-PREFIX /PREFIX-LENGTH
|
IPV6-NETWORK-PREFIX /PREFIX-LENGTH
}
Parameters
Usage Guideline
The user can use the
mac-base
command in VLAN configuration mode to create the
MAC entry that will be classified to the MAC based VLAN. If MAC based VLAN
entries are configured, the packet received by the switch regardless of the incoming
port that have a source MAC address matching an the entry will be classified to the
corresponding MAC-based VLAN. The maximum number of MAC-based VLAN
assignment entry is project dependent.
The precedence to classify the VLAN for an untagged packet is
MAC-based > Subnet-based > Protocol VLAN > Port-based VLAN
The user should use the
switchport hybrid allowed vlan
command to set the
VLAN membership for the MAC-based VLAN.
Example
This example shows how to create a MAC-based VLAN entry for the MAC address
00-80-cc-00-00-11.
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#vlan 101
DXS-3600-32S(config-vlan)#mac-base 00-80-cc-00-00-11 priority 4
DXS-3600-32S(config-vlan)#
NETWORK-PREFIX /
PREFIX-LENGTH
Specifies the network prefix and the prefix length in the form of A.B.C.D/x
IPV6-NETWORK-PREFIX /
PREFIX-LENGTH
Specities the IPv6 network prefix and the prefix length in the form of x:x:x:x:x:x:x:x/n.
The prefix length of IPv6 network address shall not greater than 64 bits.
priority
COS-VALUE
Specifies the priority for the entry. The value is a number from 0 to 7, if the priority is
not specified, the default value is 0.
Default
No subnet-based VLAN.
Command Mode
VLAN Configuration Mode.
Command Default Level
Level: 12
Usage Guideline
A subnet VLAN entry is an IP subnet-based VLAN classification rule. If an untagged
or priority-tagged IP packet is received on a port, its source IPv4 address or the
upper 64 bits of source IPv6 address will be used to match the subnet VLAN entries.
If the source IP matches the subnet of an entry, the packet will be classified to the
VLAN of this entry. If the packet is untagged, the priority will be picked up from it too.
For priority-tagged packet, its priority will not change. The number of subnet-based
VLAN entries is project dependent.
The precedence to classify an untagged packet is
MAC-based > Subnet-based > Protocol VLAN > Port-based VLAN
The user should use the
switchport hybrid allowed vlan
command to set the
VLAN membership for the subnet-based VLAN user.
Содержание DXS-3600-16S
Страница 1: ...CLI Reference Guide Product Model DXS 3600 Series Layer 2 3 Managed 10GbE Switch Release 1 10 ...
Страница 232: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 224 ...
Страница 301: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 293 ...
Страница 349: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 341 ...
Страница 494: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 486 ...
Страница 564: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 556 ...
Страница 649: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 641 ...