DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
194
12-7 clear error-log
This command is used to clear error log information.
clear error-log
12-8 show error-reboot
This command is used to show the state of the error-reboot option.
show error-reboot
Example
This example shows how to show error log information.
DXS-3600-32S#show error-log
# debug log: 1
# firmware version: 1.10.011
# level: CPU exception
# clock: 8337400 ms
# time : 2000-01-19 03:19:42
====================== SOFTWARE FATAL ERROR =======================
Invalid mutex handle : 806D6480
Current TASK : bcmARL.0
------------------------- TASK STACKTRACE ------------------------
->802ACE98
->8018C814
->8028FF44
->8028352C
->801D703C
->8013B8A4
->802AE754
->802A5E0C
->802A5D6C
**************************************************************************
# debug log: 2
# level: fatal
<The Output contunues>
Parameters
None.
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 15
Usage Guideline
The user can use the
clear error-log
command to clear the error log information.
Example
This example shows how to clear the error log information.
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#clear error-log
DXS-3600-32S(config)#
Parameters
None.
Default
None.
Command Mode
EXEC Mode.
Command Default Level
Level: 15
Содержание DXS-3600-16S
Страница 1: ...CLI Reference Guide Product Model DXS 3600 Series Layer 2 3 Managed 10GbE Switch Release 1 10 ...
Страница 232: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 224 ...
Страница 301: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 293 ...
Страница 349: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 341 ...
Страница 494: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 486 ...
Страница 564: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 556 ...
Страница 649: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 641 ...