background image

Содержание CDPS-CS4

Страница 1: ...CDPS CS4 Control System Center Operation Manual Operation Manual ...

Страница 2: ......

Страница 3: ...echnology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expre...

Страница 4: ... through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating do not block any ...

Страница 5: ...2 Rear Panel 3 6 3 Remote Control 4 6 4 IR Cable Pin Assignment 5 6 5 RS 232 Protocol 5 6 6 Telnet Commands 6 6 7 Telnet Control 9 6 8 WebGUI Control 11 6 8 1 Macro Settings 12 6 8 2 Extension Macro 14 6 8 3 Command Settings 15 6 8 4 UART Settings 16 6 8 5 Network Settings 16 6 8 6 System Settings 17 7 Connection Diagram 18 8 Specifications 19 9 Acronyms 20 ...

Страница 6: ...le indirect device control is possible using telnet allowing users to control newer more complicated devices With this product you can pre program and recall up to 16 distinct macros 8 can be directly activated via external triggers or IR remote providing for complete control over your audio and video environment 2 APPLICATIONS Smart Home Control Control Center Function Room Product Showroom Ballr...

Страница 7: ...rigger inputs with a voltage range of 0 15V triggers at 5V Supports Baud rates from 4800bps to 115200bps Supports 10 100 Ethernet network connections 6 OPERATION CONTROLS AND FUNCTIONS 6 1 Front Panel 1 2 3 4 5 6 7 8 IR COMMS INPUT REALY 1 2 3 6 4 5 1 POWER LED This LED will illuminate when the device is switched on 2 IR WINDOW Receives IR signals from the remote control to activate macros 1 8 3 I...

Страница 8: ...s within direct line of sight of the IR Blaster 3 TRIGGER IN 1 8 Connect to any device with trigger or switch functionality such as window security alarms motion detectors door switches etc Each of the 8 trigger inputs will activate the associated macro when triggered The upper row of contacts should be connected to the positive pins of your sources and the lower row of contacts should be connecte...

Страница 9: ... network to allow it to control other devices on the network and to be accessed via Telnet WebGUI The remaining 3 ports can be connected directly to other local devices you wish to control 7 USB This slot is reserved for factory firmware update only 8 POWER Flip this switch to power the unit on or off 9 DC 5V Plug the 5V DC power adapter into this port and connect it to an AC wall outlet for power...

Страница 10: ...er IR Signal NC 3 1 2 IR Signal Power Ground IR Learner 6 5 RS 232 Protocol DATA TERMINAL EQUIPMENT Pin Assignment 1 NC 2 RxD 3 TxD 4 NC 5 GND 6 NC 7 NC 8 NC 9 NC Baud Rate 4800 115200bps Data Bits 7 8 Parity None Odd Even Flow Control None Stop Bits 1 ...

Страница 11: ...eway X 0 255 SIPMODE N Set Ethernet IP mode N STATIC DHCP VER Show unit s firmware version REBOOT System reboot FADEFAULT Set all configurations to factory default ETH_FADEFAULT Set all Ethernet settings to factory default HELP Show command list Show command list HELP N Show description of command N Command Name N Show description of command N Command Name RELAY N N1 Set relay N s state N 1 8 N1 O...

Страница 12: ...d to COM port N 1 2 COM Port N1 Command Data Up to 512 ASCII characters COMCONF COM N N1 N2 N3 N4 Set the RS 232 COM port configuration N 1 2 COM Port N1 4800 9600 19200 38400 57600 115200 Baud Rate N2 7 8 Data Bits N3 NONE ODD EVEN Parity N4 1 Stop Bits MACRO STOP N Stop macro N 1 16 Port MACRO RUN N Run macro N 1 16 Port TRIGGER STATUS Show current status of all triggers TRIGGER INFO Show settin...

Страница 13: ...te All commands must be followed by a carriage return Commands are not case sensitive Some COMSEND commands may require carriage returns or other normally illegal characters within the sent Command Data To send those characters the ASCII hex value can be used when preceded by x For example x0D would be transmitted as a standard carriage return Because will interpreted as a special escape character...

Страница 14: ...s Telnet in Windows 7 click on the Start menu and type cmd in the search field then press Enter Under Windows XP go to the Start menu click on Run type cmd then press Enter Under Mac OS X go to Go Applications Utilities Terminal See below for reference Once in the CLI Command Line Interface type telnet followed by the IP address of the unit and 23 then hit Enter ...

Страница 15: ...rol Type help to list the available commands Note Commands will not be executed unless followed by a carriage return Commands are not case sensitive If the IP address is changed then the IP address required for telnet access will also change accordingly ...

Страница 16: ... unit s default static IP address is 192 168 1 50 By clicking on one of the listed devices you will be presented with the network details of that particular device If you choose you can alter the static IP network settings for the device or switch the unit into DHCP mode to automatically obtain proper network settings from a local DHCP server To switch to DHCP mode please select DHCP from the IP m...

Страница 17: ...gs Extension Macro Command Settings UART Settings Network Settings and System Settings to allow for user configuration of the unit 6 8 1 Macro Settings Click on the Macro Settings tab to execute edit the 8 primary macros These macros can be executed by activating the 8 input triggers on the back of the unit as well as via WebGUI Telnet or IR remote Each macro can contain up to 16 individual comman...

Страница 18: ...you can edit the name of the macro Type your new macro name into the box and then click the Save icon to save it Within the Macro edit window the up down arrows will change the command execution order The icon allows you to edit the delay and interface for the command The icon will delete the command Click on the icon to insert a new command before the current one Select one of the pre defined com...

Страница 19: ...e Change button Note It is strongly suggested to not set a delay time less than 100ms for system RS 232 IR and relay commands or less than 500ms for Telnet commands to ensure that the command is properly received and executed before the next command is sent When you have finished editing the macro click on Save Change 6 8 2 Extension Macro Click on the Extension Macro tab to execute edit the addit...

Страница 20: ... IR Command To learn an IR command first make sure the included IR Learner is connected to the unit s IRL port then press IR Learn within the command edit window After doing this a notice will appear in the WebGUI to send the IR signal within 5 seconds When you see this point your remote control at the IR receiver and press the button that contains the command you wish to learn A command string wi...

Страница 21: ...y be set via Telnet or RS 232 After changing a COM port s settings please click on the Save button to store the new settings 6 8 5 Network Settings Click on the Network Settings tab to change the network settings for the unit You can manually set the IP address netmask and gateway address in Static IP mode or you can obtain an IP address automatically by enabling DHCP ...

Страница 22: ...e the full system configuration including all macros to your connected PC Laptop or restore them from a previously saved configuration Finally this tab provides buttons to reset the unit to factory defaults and to reboot the unit Note Please ensure that all commands and settings have been backed up before performing an All Reset as the procedure will return all settings back to the factory default...

Страница 23: ...ENU OUT A 1 B 2 C 3 D 4 IN E 5 F 6 G 7 H 8 POWER LOCK MENU OUT A 1 B 2 C 3 D 4 IN E 5 F 6 G 7 H 8 Blind Control Lighting Control Alarm Sensor Screen Control Integrated 3rd Party Control Internet Connected Router RS 232 Otuputs IR Learner LAN Connections LAN Power Supply IP Control Enabled Device IP Control Enabled Device IP Control Enabled Device RS 232 Controllable Device RS 232 Controllable Devi...

Страница 24: ... Up to 115200bps Power Supply 5V 2 6A DC US EU standards CE FCC UL certified ESD Protection Human Body Model 12kV Air Discharge 8kV Contact Discharge Dimensions 432mm 44mm 174mm W H D Case Only 432mm 49mm 181mm W H D All Inclusive Weight 2 186g Chassis Material Metal Silkscreen Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Relative Humidity 20 90 RH ...

Страница 25: ... 9 ACRONYMS ACRONYM COMPLETE TERM CLI Command Line Interface GUI Graphical User Interface HTTP HyperText Transfer Protocol IR Infrared LAN Local Area Network PC Personal Computer USB Universal Serial Bus ...

Страница 26: ......

Страница 27: ......

Страница 28: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw ...

Отзывы: