13
functions:
(1) Macro 1:
Sequentially close relays 1 through 8 with a 100ms delay
(2) Macro 2:
Sequentially open relays 1 through 8 with a 100ms delay
(3) Macro 3:
Sequentially toggle the state of relays 1 through 8 with a
100ms delay
(4) Macro 4:
Sequentially send IR signals from emitters 1 through 8 with
a 100ms delay. The IR LED will flash on the front panel.
(5) Macro 5:
Send the command "Hello World" over COM ports 1 and
2 with a 100ms delay between commands.
Click on the “Edit” icon ( ) to edit each button’s macro. At the top
of the Macro edit window is a text field where you can edit the name
of the macro. Type your new macro name into the box and then click
the “Save” icon ( ) to save it.
Within the Macro edit window the up/down arrows will change
the command execution order. The (
) icon allows you to edit the
delay and interface for the command. The ( ) icon will delete the
command.
Click on the ( ) icon to insert a new command before the current
one. Select one of the pre-defined commands from the list. (Details on
how to create these pre-defined commands are later in this section.)
After selecting a command, you will need to choose the delay and
interface for the command.
(1) Delay(ms):
This setting is the length of time to wait before sending
the next command and is set in milliseconds.
(2) Interface:
The interface for sending commands can be set to
Содержание CDPS-CS4