15
6.8.3 Command Settings
Click on the “Command Settings” tab to create, edit or delete
commands. The number of commands that can be stored in the unit
is limited by memory. It is generally recommended that commands
be under 128 characters long (including spaces). However, if longer
commands are needed there is limited support for commands up to
512 characters long. In this case the number of (up to) 512 character
commands is limited to 32 and the remaining 96 commands must be
under 128 characters.
(1) Renaming Command:
You may rename the command, if you wish,
by changing the text in the “Command Label” field.
(2) Learning IR Command:
To learn an IR command, first make sure
the included IR Learner is connected to the unit’s IRL port, then
press “IR Learn” within the command edit window. After doing this
a notice will appear in the WebGUI to send the IR signal within 5
seconds. When you see this, point your remote control at the IR
receiver and press the button that contains the command you
wish to learn. A command string will then appear in the text entry
window containing the information captured from the IR remote.
(3) Entering Text Command:
For plain text commands, simply enter the
text command into the entry window.
Once the command setting is complete please click on the “Save
Change” button to save the new command.
Note: Some commands may require a carriage return (e.g. \r or \x0D)
at the end to be accepted by the destination device.