202
Administration
Option 5 - Quit
will close the current session and the TCP connection.
Only for the administrator users:
Typing
all.escape_char
or
sN.escape_char
from
the sniff session or “send message mode” will make the ACS show the
previous menu. The first regular sessions will not be allowed to return to
the menu. If you kill all regular sessions using the option 4, your session
initiates as a regular session automatically.
VI Method - Involved parameters and passed values
Session sniffing involves the following parameters in the
/etc/portslave/
pslave.conf
:
•
all.admin_users
- This parameter determines which users can
receive the sniff menu. When users want access per port to be
controlled by administrators, this parameter is obligatory and
authType
must not be none. User groups (defined with the
parameter conf.group) can be used in combination with user
names in the parameter list. Example values: peter, john,
user_group.
•
all.sniff_mode
- This parameter determines what other users
connected to the very same port (see parameter
admin_users
below) can see of the session of the first connected user (main
session):
in
shows data written to the port,
out
shows data
received from the port, and i/o shows both streams, whereas
no
means sniffing is not permitted.The second and later sessions
are called sniff sessions and this feature is activated whenever
the protocol parameter is set to
socket_ssh
,
socket_server,
or
socket_server_ssh.
Example value:
out
.
•
all.escape_char
- This parameter determines which character
must be typed to make the session enter menu mode. The possi-
ble values are <CTRL-a> to <CTRL-z>. Represent the CTRL
with character: ^. This parameter is only valid when the port
protocol is
socket_server
or
socket_ssh
. Default value is ^z.
•
all.multiple_sessions
- If it is configured as
no
, only two users
can connect to the same port simultaneously. If it is configured
as
yes
, more than two simultaneous users can connect to the
same serial port. A “Sniffer menu” will be presented to the user
and they can choose either to open a sniff session; to open a
read and/or write session; to cancel a connection; or to send a
message to other users connected to the same serial port. If it is
Содержание AlterPath ACS
Страница 16: ...xvi Table of Contents...
Страница 29: ...13 This page has been left intentionally blank...
Страница 30: ...14 Preface...
Страница 68: ...52 Device Access...
Страница 86: ...70 Authentication Step 5 Saving changes To save the configuration run the command saveconf...
Страница 96: ...80 Authentication Save the configuration to flash 2 cli config savetoflash...
Страница 114: ...98 Authentication...
Страница 204: ...188 Administration To exit the CLI mode and return to ACS s shell issue the command cli quit...
Страница 268: ...252 Power Management with AlterPath PM Integration...
Страница 304: ...288 PCMCIA Cards Integration...
Страница 338: ...322 Profile Configuration...
Страница 364: ...348 Additional Features and Applications...
Страница 376: ...360 Appendix A New User Background Information...
Страница 406: ...390 Appendix C Cabling and Hardware Information This page has been left intentionally blank...
Страница 418: ...402 List of Tables...
Страница 420: ...404 List of Figures...