5. Installation
34
PNEG-499
Cycle Plus Pan Feeder
Winch Kit Installation (Continued)
The recommended spacing between the winch cable at the hopper and the drop lines on each side of the
hopper is 1' (0.3 m). A 3' (0.9 m) space is recommended between the cable at the drive unit and the drop
lines on each side of the drive unit.
Figure 5AF
Cable and Winch Installation
For wood frame installation install screw hooks along the line at the recommended spacing. Screw hooks
into the ceiling supports or rafters the full length of the threads to prevent bending. For metal frame
installations, some support fabrication may be necessary in order to install pulleys at the recommended
spacing. For additional information and recommendations, contact a Cumberland representative.
The openings of the screw hooks must point away from the direction of cable travel when the winch raises
the feeder. If the distance raised is greater than the distance between drop spacings, stagger the hooks
3" (8 cm) to each side of the line to prevent the cable clamp sleeves from catching on the pulleys.
Figure 5AG
Ref #
Description
B
1-3/4" (4.445 cm) Pulley
C
2-1/2" (6.35 cm) Pulley
D
Drive Unit
E
Nylon Elbow
Direction of cable travel
when raising feeders or
direction towards winch.
Ref #
Description
F
Rafter
Содержание PNEG-499
Страница 1: ...PNEG 499 Cycle Plus Pan Feeder Installation and Operation Manual PNEG 499 Date 01 01 15...
Страница 2: ...2 PNEG 499 Cycle Plus Pan Feeder...
Страница 48: ...48 PNEG 499 Cycle Plus Pan Feeder NOTES...
Страница 52: ...52 PNEG 499 Cycle Plus Pan Feeder NOTES...
Страница 53: ...7 Parts List PNEG 499 Cycle Plus Pan Feeder 53 Grilled Centerhouse Control Unit Components...