Connecting the Power and Testing the Motor
1. Refer to
Tubular Motor Tester Wiring Diagram, page 51
for a description of the test cable. Construct
and connect the test cable to the motor cable. Match the wire colors and connect the power.
2. Remove the yellow protective cap from the limit switch adjustments buttons.
3. Press both the limit switch adjustment buttons inward. (The buttons will automatically remain
locked.)
4. Check that the tubular motor (89) rotates properly when the switch is turned ON.
5. Disconnect the electrical power while installing or adjusting the curtains.
NOTE:
Somfy recommends using a test cable to set the motor limits, and to make sure the system
is operating properly before the final electrical connection is made.
NOTE:
Refer to
Tubular Motor Tester Wiring Diagram, page 51
for test cable.
Figure 3-45
Connecting the power and testing the motor