Crystal Vision
Using the front control panel
TANDEM 3G User Manual R1.4
44
23/04/2012
Preset controls
From the STATUS top menu rotate the shaft control to select the Presets menu. Press F1 and
then rotate the shaft control to access the presets menu options. To enter a sub menu once
selected press ENTER and use the shaft control to traverse the sub menu.
Menu
Comment
Factory defaults
Rotate the shaft control to show the defaults menu.
Press F1 to select and press F4 to action.
Factory reset
Rotate the shaft control to show the factory reset menu.
Press F1 to select and press F4 to action.
Enable GPI
control of
presets
Rotate the shaft control to show the GPI preset control.
Press F1 and rotate the shaft control to select.
Enable, Disable
Selecting enable allows the recall of previously saved user
configurations via GPI inputs 1-4.
Preset
location 1
Rotate the shaft control to show the preset save/recall menu.
Press F1 and rotate the shaft control to select the chosen location 1-16.
Press F1 to enter menu and press F3 to save the current configuration.
Press F4 to recall a previously saved board configuration.
Preset
location 16
Preset menu and factory reset
Up to 16-user defined configurations may be stored and recalled either from the board control,
active front panel, Statesman or through the use of external GPIs. Presets store the board setup
data including operating mode card status. The presets are numbered 1-16.
Note:
Care should be taken when storing presets that the desired configuration is not changed by any external
input prior to saving.
Saving and recalling presets
The current board settings can be saved in one of 16 locations to be recalled as desired. This
allows the user to store and recall up to 16 different configurations for later use.
To save the current settings, select the preset location and press ENTER. Select the save
option and press ENTER to write the current settings into this location.
Note:
If the selected location contains previously saved setting information it will be over-
written by the new setting data.
To recall previously stored setting information, again choose the selected location and select
recall, pressing ENTER will recall the stored configuration.
The recalling of previously stored presets can also be implemented externally via the GPI port.
To use this facility, enable GPI control of presets.