Installation
The Indigo DT range of frames is capable of housing
the Crystal Vision range of optical modules. Although
these modules are not capable of causing personal
injury, care should be exercised when exposing
unshielded optical signals not to look directly into the
light beam.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
2.2 Rack mounting and ventilation
The Indigo series of desk top boxes are designed for tabletop use, however they must
have adequate ventilation. On no account should the side ventilation grilles be
blocked.
If the optional rack ears are fitted, and the unit is installed in a standard 19" rack, cool
air circulation should be available and both side ventilation grilles should be
unobstructed.
Indigo DT airflow
Install the Indigo DT in a standard 19" rack as follows:
•
Fit the optional rack ears
•
Mount in the rack and secure via the rack ears
•
Allow adequate space for the fan intake at the right hand side and the
exhaust through the left hand side (viewed from front)
Note:
It is possible to operate the frame with the front panel open, however the frame
may not meet electromagnetic compatibility (EMC) requirements in this
condition.
Indigo DT User Manual R1.8