Then click on the ‘Store’ button to write the new value into the frame. This will
take a few seconds. You will then need to re-boot the frame (as described in the
"Resetting the Frame" below) for the setting to take effect.
Checking
The frame should now be ready for SNMP operation. You can check this by
setting a SNMP Manager, or MIB browser, to the frame IP address and
performing an SNMP walk of the ‘private’ section of the Object ID tree.
See below for a screen shot of a successful walk; in this case of a 4U frame
containing two boards.
If you do not see something similar to this, then the frame may need to be reset
to activate the SNMP licence. The frame will report the presence of the licence
even if it has not been activated by a reset. The same walk of an unlicensed
frame gives the results below.