Crystal Vision
Trouble shooting
Replacing the mains input fuses
The mains input fuse is fitted inside the IEC 320 connector at the rear of the frame. A
spare fuse is also stored inside the connector. The fuse can only be accessed when
the power cord is disconnected.
The sequence is as follows:
•
Disconnect the power cord from the rear of the frame
•
Using a flat bladed screwdriver or similar tool gently lever out the fuse
drawer from the IEC connector using the tab visible at the bottom of the
connector depression
•
Remove the defective fuse and replace with either the spare fuse or with
a 5A, 250V time delay fuse
•
Replace the fuse drawer and reconnect the power cord
Rear connectors showing IEC mains input and fuse tray with
main and spare fuses
If a fuse blows repeatedly this indicates a fault either in the power supply module or
elsewhere. Return the frame and/or power supply to the manufacturer or dealer for
repair.
Note:
Replace the fuse only with one of the same type and rating (5A, 250V time
delay).
Software upgrades
Software upgrades for the Indigo DTSE front panel are done via the Ethernet
connection. See the Indigo active front panel manual for information concerning
remote software uploading.
Indigo DT User Manual R1.8
30
05 July 2018