Crystal Vision
Appendix 1
12 Appendix 1
12.1 Indigo Frame Software prior to v4.6
Prior to frame software version 4.6, Ethernet-enabled Indigo frames used an entirely different
web interface. The following is documented for users of older frame software.
Setting up and connecting
The frame can be connected to a network port or directly to a PC from the rear panel RJ45 port
labelled Ethernet. If connecting directly to a PC, a CAT5 crossover cable will be required.
Connecting to a network port hub uses a straight CAT5 cable.
To access the internal web page set the frame to the default IP address. Open up your PC web
browser and set its search to http://10.0.0.201 and select ‘go to’. This is the default IP address,
the sub-mask being 255.255.255.0. After a dialogue box has briefly appeared the Indigo main
status page will be displayed. This page will give a large amount of status information about the
frame and its power supplies. From the web page several options are available such as
changing the IP address and frame naming.
Note:
Once the IP address has been changed the status page will be accessible via this
new address.
Indigo 1 User Manual R1.14
76
27 February 2020