Crystal Vision
Maintenance
9.3 Replacing the mains input fuses
This information refers to all frames except the Indigo 1-DP range.
The mains input fuse is fitted inside the IEC 320 connector at the rear of the frame. A spare
fuse is also stored inside the connector. The fuse can only be accessed when the power cord
is disconnected.
The sequence is as follows:
•
Disconnect the power cord from the rear of the frame
•
Using a flat bladed screwdriver or similar tool gently lever out the fuse drawer from the
IEC connector using the tab visible at the bottom of the connector depression
•
Remove the defective fuse and replace with either the spare fuse or with a 5A, 250V time
delay fuse
•
Replace the fuse drawer and reconnect the power cord
Rear connectors showing IEC mains input and fuse tray
with main and spare fuses
If a fuse blows repeatedly this indicates a fault either in the power supply module or
elsewhere. Return the frame and/or power supply to the manufacturer or dealer for repair.
Note:
Replace the fuse only with one of the same type and rating (5A, 250V time delay).
Indigo 1 User Manual R1.14
70
27 February 2020