Crystal Vision
Maintenance
Inserting a PSU
To insert a PSU proceed as follows:
•
Offer up the PSU to the frame guide rails – it may help to turn the handle fully outwards to
clear the panel hinge
•
Carefully push the PSU all the way into its socket
•
The PS-80i module is handed and can only be fitted in its correct position. See Installation
chapter, left/right side conversion.
Dual power supplies motherboard
The PS-80i power supply modules are mounted into the Indigo 1-DP frame range by way of a
carrier board. This carrier board (which remains in situ) contains the CPU, alarm relay and low
voltage fusing for the frame bays. There are no user adjustments on this carrier board so
removal should not normally be necessary.
Dual PSU carrier board assembly
A pin at the front end of the central runner retains the dual power supply carrier board. This
pin is press fitted into a hole in the chassis. To remove the carrier board lift the front of the
runner to disengage the pin and pull forward to unplug and remove.
Refit in reverse ensuring that the pin is fully located into the hole in the chassis.