Recovery Mode
On power up, the frame will enter ‘Recovery Mode’ if it detects corrupt firmware,
or
if
configuration switch S2 on the upper PCB is in the left position. When the frame is accessed
by an internet browser using either the original IP address before firmware corruption
occurred or the default IP address 10.0.0.201, the following is displayed:
The screen will ask the user to select an image file to repair or to upgrade the firmware. Do not
attempt to do this without specific instruction from Crystal Vision or its representatives. If,
however, configuration switch S2 on the upper PCB has been put into the left position with a
view to changing the IP address then the user can just select the ‘Network Setup’ page:
Enter the desired IP and netmask addresses. Enter the gateway address if necessary (else
leave at 0.0.0.0).
Press ‘Set’ to enter the values, then reboot when all fields have been entered. If configuration
switch S2 on the upper PCB is in the left position, it will be necessary to return it to the right
position and reboot to prevent recovery mode being entered again.