Installation
6-10
6.6 Air compressor installation
The air compressor, if supplied by Cryomech, should be installed according to the
manufacturer's specifications included in the air compressor's instruction manual. The
manufacturer’s instruction manual is included with the air compressor. Proper installation
and mounting of the air compressor is crucial to the safe operation and longevity of the
equipment.
CAUTION
The air compressor must be installed and operated according to the manufacturer’s
specifications included in the air compressor’s instruction manual.
Failure to follow
the manufacturer’s instructions will void the warranty.
Do not proceed further until the air compressor manufacturer’s instruction manual has
been completely read and understood.
6.6.1 Position the air compressor
•
Locate the air compressor within 50 ft (15 m) of the N
2
generator/filter bank panel. If
greater separation is required additional copper tubing will be needed.
•
Position the air compressor so that the oil pressure gauge and receiver tank gauge
are visible. Allow at least 2 ft (0.6 m) of open space behind the belt guard to allow for
a sufficient air flow required to cool the air compressor.
•
When positioning the air compressor make certain the receiver tank drain valve is
accessible and there is sufficient space around the air compressor to perform
periodic maintenance.
6.6.2 Mount the air compressor
•
Mounting pad kits are included with the air compressor, if supplied by Cryomech.
•
Consult the air compressor’s instruction manual for complete mounting instructions.
CAUTION
If the air compressor must be bolted to the floor, please pay special attention to the
mounting instructions included in Section 3 of the air compressor’s instruction
manual.
Failure to mount the air compressor according to the manufacturer’s
instructions will void the warranty.
6.6.3 Connect a drain line to the receiver/tank drain valve
If needed, connect a drain line to the receiver/tank drain valve. Extend tubing or piping
away from the unit to provide safe and convenient removal of excess moisture. Dispose
of all the condensate in conformity with current local environmental regulations.
Содержание LNP-40
Страница 1: ...Model LNP 40 Liquid Nitrogen Plant INSTALLATION OPERATION and ROUTINE MAINTENANCE MANUAL...
Страница 4: ...1 1 N Section 1 Overview...
Страница 10: ...2 1 N Section 2 Warranty...
Страница 13: ...3 2 N Section 3 Safety...
Страница 25: ...4 1 N Section 4 Inspection and Unpacking...
Страница 29: ...5 3 N Section 5 Specifications...
Страница 50: ...6 1 N Section 6 Installation...
Страница 67: ...7 2 N Section 7 Operation...
Страница 87: ...8 1 N Section 8 Routine Maintenance...
Страница 98: ...Appendix Spray Lubricant Instructions...