36
Alarm Functions
F10 LOW BATTERY ALARM OFF (RECHARGE) SET POINT
Once the Low Battery Alarm is activated, recharging the battery to
this point turns the alarm OFF. This recharged point must always be
at least 10% higher than Low Battery Line closure point.
DEFAULT: 70%
RANGE: 0%-70%
STEP: 5%
F11 LOW BATTERY ALARM ON SET POINT
Sets when the Low Battery Alarm goes ON point based on percent of
Amp-hours discharged. F-11 is displayed in percent: i.e. 10 is 10%
discharged. F-11 may set anywhere in its range but at least 10% below
the F10 Low Battery Alarm OFF Set Point set point.
DEFAULT: 80%
RANGE: 10%-80%
STEP: 5%
Amp-Hour
Capacity of
Battery
E.G. 100 AH
F-10
TURNS ON Low Bat-
tery Alarm at a set %
of rate compensated
AHrs Discharged
ALARM ON
Settable Range
70% Discharged
10% Discharged
80% Discharged
F-11
TURNS OFF
Low
Battery Alarm when
AHrs are restored
Refer to F14 in the Owner's Manual
Functions F10, F11, and F12 define operation of the Visual Low Battery
Alarm as follows:
ALARM OFF