Once you have completed ALL instructions on Page 17, insert the voltage sense
wire fuse, then the meter power fuse. (BLUE wire fuse first, RED wire fuse
last!) The fuse should be in a fuse holder and should be connected in a smooth
motion. A "ragged" power up may cause a meter lock up. Both the bar graph
and digital display should come on.
Factory Default Settings
Your Meter comes on in the
(Volts) mode with the display flashing to
indicate that it has been powered up from the de-powered state. (see page 26)
Left untouched for 10 minutes, Your Meter will go to "sleep", turning off the
digital display leaving only the bar graph on. (This is a power saving feature.)
Touching either the
SEL
or
SET
buttons will return Your Meter to the function
Your Meter was in when it went to "sleep".
Your Meter is designed to work "out of the box". The factory default values are
appropriate for a moderate capacity 12V liquid lead acid battery and a typical
user display and function setup. Often the only change that must be made is
setting the battery capacity. You may also have to set the appropriate Peukert's
exponent for your battery ( See page 24). Special functions and display options
are described beginning on Page 27.
Your Meter's factory default settings are:
1.
Automatic Scanning of V, A, Ahrs, and time will be OFF.
2.
Sleep Mode is ON. Turns digital display off after 10 min.
3.
Charge Efficiency Factor (CEF) equals 90% and learn CEF mode is on.
4.
Charged Parameters: Voltage =13.2, Charged Current =2%. The bat-
tery must exceed 13.2V and the current must be less, in Amps, than 2% of
declared capacity for 5 minutes for Your Meter to consider the battery full.
5.
Battery capacity set to 200 Amp-hours.
6.
Peukert Exponent = 1.25.
Start Up