Synchronizing Your Meter
Synchronize Your Meter to a full battery.
After installing Your Meter, charge the battery until the far right Green
LED begins flashing, which indicates the Charged Parameters have been
met. Amp-hours will have started at
0
and counted up as a positive num-
ber. As you begin discharging the battery, the LED will stop flashing and
the numeric Amp-hour display resets to
0
. Your Meter is shipped from
the factory assuming a 200 Amp-hour battery. Your battery may be a
different size. To change battery size, see Page 21.
Staying in Sync, Removing Accumulated Negative Ahrs.
Should Your Meter ever become out of sync with the battery state-of-
charge simply charge until the far right LED flashes Green. You may also
get back in sync by charging until the battery is full and then resetting the
Amp-hours to zero through the
RESET
function.
If Your Meter should accumulate a negative number in the Amp-hour
display you will have to charge until you meet the conditions for a recal-
culation of the Charging Efficiency (CEF) as described on Pages 22 & 23.
If you do not meet all five of the conditions listed below you will not get
a recalculation of the CEF and a reset to Zero Ahrs consumed.
CONDITIONS TO RESET TO ZERO
1) Discharge 10% of declared battery capacity to trigger algorithim
2) Recharge until 100% of the Kwhrs removed have been returned.
3) The Voltage must be above the Charged Voltage Parameter.
4) The current must be below the Charge Current Parameter.
5) Conditions 3 & 4 must be met for 5 minutes (1 min. for AE default)