43
Troubleshooting
Condition
Suggestion
No lights or display
Check Power Connections
Reset meter (Page 32)
No keyboard response
Check Lock is not invoked
Reset meter (Page 32)
Time Remaining Not
Check Battery Capacity (Page 21)
Accurate
Check Temperature Coef. (Page 35)
Check Peukert Exponent (Page 26)
Digital Display Dim
Clean front panel photo-sensor
(Between A and Ah lights)
Current Polarity Reversed
Current Shunt leads reversed. (Page 13)
Intermittent Operation
Corrosion or loose wires. Loosen and
reconnect all rear panel connections.
Check voltage sense and shunt wiring
at battery location.
Accumulates Negative
Charge Parameters not met. Check
Amp-hour reading
Charged Parameter values, Has 100% of
Kwhrs been returned? Charging Current is
not passing through shunt. (Pages 13,22,23,
& Function F04)
CECO warrants that Your Meter will measure Voltage, Amperage, and
Amp-Hours within the published specifications. The Time remaining and
LED bar graph functions are complicated and require appropriate user set
up and are therefore beyond the control of CECO and are not covered by
warranty. Similarly installation wiring and specific applications are be-
yond our control and are not covered by warranty. See Page 51.