background image

 

-

 Page  3 -

 

 

1. 

Trouble shooting via Service tool for Leveller, Shelter and Door

 

 As a tool for certified Crawford service and installation staff, the service tool can 

be connected to the leveller board, connector X2 in the control box. The service 
tool has two buttons, called RIGHT BUTTON (SW2) and LEFT BUTTON (SW1). 

 

 If an error occurs that trigs an error code, the display will show the current error 

code. If several error codes exist at the same time, the display will alternate 
between the existing error codes. 

 

 With the tool it is possible to see the fifteenth latest errors from the leveller and 

fifteenth latest errors from the door. 

 

 

As default, the state of the leveller, shelter or the door will be displayed on the control box 

and on the display of the service tool. 

 
 
 

Indicating leveller in resting position, closed door (CDM9 and 
S9 sensor) and shelter off. 
 

 

Flashing when shelter starts until door is open. 

 

 
Indicating opened door (CDM9 or S9 sensor). 

 

 
Indicating dock leveller lifts. 

 

 
Indicating extend swing lip or telescopic lip. 

 

 
Indicating leveller in floating position. 

 

“Winter mode”. The shelter function is activated. 

 

“Summer mode”. The shelter function is not activated. 

 

Truck in position. 

 

 A dot in the lower right corner of the display indicates that the automatic closing is 
activated.

 

 

 
Indicating Auto close of the door. 

 

Control unit locked. 

Содержание ECS 950

Страница 1: ...Service tool manual ECS 950 950 Docking Approv Godk Doc No Rev O K046804 2010 12 01 KHm GB...

Страница 2: ...display 10 1 10 Automatic closing activated 10 2 1 Normal Service Technician work procedure 15 2 2 How do I do to 17 2 2 1 See a non changeable register 17 2 2 2 Set the limits for service interval 17...

Страница 3: ...rors from the leveller and fifteenth latest errors from the door As default the state of the leveller shelter or the door will be displayed on the control box and on the display of the service tool In...

Страница 4: ...choices The LEFT BUTTON SW1 will in some menus increase the value by 1 In other menus the value shown is set to 0 if you press the LEFT BUTTON SW1 An overview of these choices can be seen in the colu...

Страница 5: ...val Since the Service interval in number of door cycles is set in menu d07 one needs to reset d04 at service Since the Service interval in operating time is set in menu d08 one needs to reset d06 at s...

Страница 6: ...p of CDM9 operator Refresh No d0C Shows the active door errors with highest priority first 1 No d0d Set functionality of Auto close timer No C card 0 Close the door and retracts the shelter 1 Close th...

Страница 7: ...o 1 6 3 and 1 6 4 Remember that it is only possible to reset the trip meter and not the total counter or Odometer 8 Now one may change the service interval if there is a need for another interval than...

Страница 8: ...eveller shelter or the door B Press LEFT BUTTON SW1 3 times menu d is showed Select Door submenu by RIGHT BUTTON SW2 d01 is showed C Press SW1 several times until submenu d07 or d08 see Table 1 is sho...

Страница 9: ...d01 is showed C Press SW1 several times until submenu d04 is showed Select the submenu by RIGHT BUTTON SW2 The display now shows the number of cycles that is stored for example 99 D Press the LEFT BU...

Страница 10: ...01 is showed C Press SW1 several times until submenu d0C is showed Select the submenu by RIGHT BUTTON SW2 The display now shows the error with the highest priority D Press the LEFT BUTTON SW1 to see n...

Страница 11: ...the control box in immediate proximity to the connection blocks In order to prevent the components from being destroyed by static electricity during installation or service work any staff coming into...

Страница 12: ...rmation about errors that recently appeared on the leveller While troubleshooting the leveller you can find important information in this menu If you need to contact CPAB helpdesk regarding the contro...

Страница 13: ...6 2A 6 8A 7 4A 8 0A 8 6A 9 2A 1 Yes L13 Cross traffic switch S6 exist or not U00 Cross traffic switch installed U01 No switch installed door located behind leveller default 1 Yes L14 Lift swing lip e...

Страница 14: ...shelter open door U01 Close door stop shelter U02 Open door outside U03 Autoclose of door on off U04 doors extra safety default U05 Close door U06 Open door open in the lid disconnected 1 Yes L26 The...

Страница 15: ...1 and save The functions are now as pre set from factory 1 Yes Table 2 Functions SHELTER menu SW1 Save S01 Show the total number of shelter cycles x1 Refresh No S02 Shelter type default SIR U00 SIR U0...

Страница 16: ...the trip meter and not the total counter or Odometer It is also possibly to do a total service reset via submenu L20 which is explained in detail in 2 2 5 8 Now one may change the service interval if...

Страница 17: ...L is showed Enter Leveller submenu by RIGHT BUTTON SW2 L01 is showed C Press SW1 several times until submenu L06 or L07 see Table 1 is showed Enter for example the submenu L06 by RIGHT BUTTON SW2 the...

Страница 18: ...it from service menu Alternatively press LEFT BUTTON SW1 continuously for 2sec to exit from service menu G The display now goes back to normal operation showing the state of the leveller shelter or th...

Страница 19: ...error in the RAM memory area on the Leveller board has been detected The error is considered as a fatal error and the entire system will be halted until the power supply has been switched off F10 Fau...

Страница 20: ...t from service menu N The display now goes back to normal operation showing the state of the leveller shelter or the door Alternatively the display showing active error codes 2 4 Indication of time fo...

Страница 21: ...ress LEFT BUTTON SW1 continuously for 2sec to exit from service menu F The display now goes back to normal operation showing the state of the leveller shelter or the door 3 1 2 Set Shelter type A The...

Страница 22: ...ton S8 OPEN DOOR S00 will be displayed for 2 sec and winter mode is selected Function to summer mode Shelter function disabled The Leveller in resting position door closed and the shelter switched off...

Страница 23: ...the control box in immediate proximity to the connection blocks In order to prevent the components from being destroyed by static electricity during installation or service work any staff coming into...

Отзывы: