Page 21 -
3:1
SHELTER
- Menu choices in the display is [S]
A brief description of the menu choices available by SW1 and SW2 are shown in Table 3 for
Shelters, above (page 15).
The table shows information about the function of the SW1 button (which is different in the
different menus) and if it is possible to store values in the internal memory within the menu.
3.1.1 See a non changeable register:
The non changeable register is S01.
A.
The display shows the state of the leveller, shelter or the door.
B.
Press LEFT BUTTON SW1 2 times, menu [S] is showed. Enter Shelter submenu by
RIGHT BUTTON SW2 S01 is showed.
C.
Enter the submenu by RIGHT BUTTON SW2, the display shows the total number of
shelter cycles.
D.
Press SW2 to exit back to submenu.
E.
Press LEFT BUTTON (SW1) several times until the display shows [S], press two more
time on SW1 to exit from service menu.
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service
menu.
F.
The display now goes back to normal operation showing the state of the leveller, shelter or
the door.
3.1.2 Set Shelter type
A.
The display shows the state of the leveller, shelter or the door.
B.
Press LEFT BUTTON SW1 2 times, menu [S] is showed. Enter Shelter submenu by
RIGHT BUTTON SW2 S01 is showed.
C.
Press SW1, submenu S02 is showed. Enter the submenu by RIGHT BUTTON SW2, the
display shows the pre-set shelter type.
D.
Use the LEFT BUTTON (SW1) to step to the next type until the display shows the type of
your choice. (in this case U00 or U01 see Table 3).
E.
To leave the menu
without
saving
the new value press SW2. To leave the menu
and save
the value, keep RIGHT BUTTON (SW2) pressed while pressing LEFT BUTTON (SW1).
F.
Press LEFT BUTTON (SW1), the display shows [S], press two more time on SW1 to exit
from service menu.
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service
menu.
G.
The display now goes back to normal operation showing the state of the leveller, shelter or
the door.