1:6 How do I do to…? 

 

1.6.1. 

See a non changeable register: 

The non changeable registers are d01, d03, d05, d0b and d0C.

 

 
A.

 

The display shows the state of the leveller, shelter or the door. 

B.

 

Press LEFT BUTTON SW1 3 times, menu [d] is showed. Select Door submenu by RIGHT 
BUTTON SW2 d01 is showed. 

C.

 

Press SW1 several times until submenu d03 is showed. Select the submenu by RIGHT BUTTON 
SW2, the display shows the total number of door cycles. (If C-card: x1000) 

D.

 

Press SW2 to exit back to submenu. 

E.

 

The display now shows d03. Use the LEFT BUTTON (SW1) to step to the next submenu until 
the display shows the menu of your choice (in this case d05, see Table 1). 

F.

 

Press the RIGHT BUTTON (SW2) to activate the chosen submenu d05. 

G.

 

The display will now show the total operating time (for example the value ”19”). This means that 
the door has been powered for 19 days and nights (456h). The value shown is continuously 
updated. 

H.

 

Press the RIGHT BUTTON (SW2) to exit back to the submenu. 

I.

 

Press LEFT BUTTON (SW1) several times until the display shows [d], press one more time on 
SW1 to exit from service menu. 
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service menu. 

J.

 

The display now goes back to normal operation showing the state of the leveller, shelter or the 
door. 

1.6.2. 

Set the limits for service interval: 

A.

 

The display shows the state of the leveller, shelter or the door. 

B.

 

Press LEFT BUTTON SW1 3 times, menu [d] is showed. Select Door submenu by RIGHT 
BUTTON SW2 d01 is showed. 

C.

 

Press SW1 several times until submenu d07 or d08 (see Table 1) is showed. Select for example 
the submenu d07 by RIGHT BUTTON SW2, the display now shows the value for the previous 
setting, for example ”190”, meaning 190 000 cycles. 

D.

 

Press the LEFT BUTTON (SW1) to increase the value for the service interval in number of door 
cycles (x1000). The value shown will now increase by 1 (1000 cycles). If the button is pressed a 
little while, the fast stepping function activates. When the value goes above 999 it starts over to 
0. 

E.

 

To leave the menu 

without

 

saving

 the new value press SW2. To leave the menu 

and save

 the 

value, keep RIGHT BUTTON (SW2) pressed while pressing LEFT BUTTON (SW1). 

F.

 

Press LEFT BUTTON (SW1) several times until the display shows [d], press one more time on 
SW1 to exit from service menu. 
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service menu. 

G.

 

The display now goes back to normal operation showing the state of the leveller, shelter or the 
door. 

 

1.6.3. 

Reset the operating time counter: 

A.

 

The display shows the state of the leveller, shelter or the door. 

B.

 

Press LEFT BUTTON SW1 3 times, menu [d] is showed. Select Door submenu by RIGHT 
BUTTON SW2 d01 is showed. 

C.

 

Press SW1 several times until submenu d06 is showed. Select the submenu by RIGHT BUTTON 
SW2. The display now shows the operating time in days that is stored in the internal memory, for 
example 23 which means 23 days and nights. 

Содержание ECS 950

Страница 1: ...Service tool manual ECS 950 950 Docking Approv Godk Doc No Rev O K046804 2010 12 01 KHm GB...

Страница 2: ...display 10 1 10 Automatic closing activated 10 2 1 Normal Service Technician work procedure 15 2 2 How do I do to 17 2 2 1 See a non changeable register 17 2 2 2 Set the limits for service interval 17...

Страница 3: ...rors from the leveller and fifteenth latest errors from the door As default the state of the leveller shelter or the door will be displayed on the control box and on the display of the service tool In...

Страница 4: ...choices The LEFT BUTTON SW1 will in some menus increase the value by 1 In other menus the value shown is set to 0 if you press the LEFT BUTTON SW1 An overview of these choices can be seen in the colu...

Страница 5: ...val Since the Service interval in number of door cycles is set in menu d07 one needs to reset d04 at service Since the Service interval in operating time is set in menu d08 one needs to reset d06 at s...

Страница 6: ...p of CDM9 operator Refresh No d0C Shows the active door errors with highest priority first 1 No d0d Set functionality of Auto close timer No C card 0 Close the door and retracts the shelter 1 Close th...

Страница 7: ...o 1 6 3 and 1 6 4 Remember that it is only possible to reset the trip meter and not the total counter or Odometer 8 Now one may change the service interval if there is a need for another interval than...

Страница 8: ...eveller shelter or the door B Press LEFT BUTTON SW1 3 times menu d is showed Select Door submenu by RIGHT BUTTON SW2 d01 is showed C Press SW1 several times until submenu d07 or d08 see Table 1 is sho...

Страница 9: ...d01 is showed C Press SW1 several times until submenu d04 is showed Select the submenu by RIGHT BUTTON SW2 The display now shows the number of cycles that is stored for example 99 D Press the LEFT BU...

Страница 10: ...01 is showed C Press SW1 several times until submenu d0C is showed Select the submenu by RIGHT BUTTON SW2 The display now shows the error with the highest priority D Press the LEFT BUTTON SW1 to see n...

Страница 11: ...the control box in immediate proximity to the connection blocks In order to prevent the components from being destroyed by static electricity during installation or service work any staff coming into...

Страница 12: ...rmation about errors that recently appeared on the leveller While troubleshooting the leveller you can find important information in this menu If you need to contact CPAB helpdesk regarding the contro...

Страница 13: ...6 2A 6 8A 7 4A 8 0A 8 6A 9 2A 1 Yes L13 Cross traffic switch S6 exist or not U00 Cross traffic switch installed U01 No switch installed door located behind leveller default 1 Yes L14 Lift swing lip e...

Страница 14: ...shelter open door U01 Close door stop shelter U02 Open door outside U03 Autoclose of door on off U04 doors extra safety default U05 Close door U06 Open door open in the lid disconnected 1 Yes L26 The...

Страница 15: ...1 and save The functions are now as pre set from factory 1 Yes Table 2 Functions SHELTER menu SW1 Save S01 Show the total number of shelter cycles x1 Refresh No S02 Shelter type default SIR U00 SIR U0...

Страница 16: ...the trip meter and not the total counter or Odometer It is also possibly to do a total service reset via submenu L20 which is explained in detail in 2 2 5 8 Now one may change the service interval if...

Страница 17: ...L is showed Enter Leveller submenu by RIGHT BUTTON SW2 L01 is showed C Press SW1 several times until submenu L06 or L07 see Table 1 is showed Enter for example the submenu L06 by RIGHT BUTTON SW2 the...

Страница 18: ...it from service menu Alternatively press LEFT BUTTON SW1 continuously for 2sec to exit from service menu G The display now goes back to normal operation showing the state of the leveller shelter or th...

Страница 19: ...error in the RAM memory area on the Leveller board has been detected The error is considered as a fatal error and the entire system will be halted until the power supply has been switched off F10 Fau...

Страница 20: ...t from service menu N The display now goes back to normal operation showing the state of the leveller shelter or the door Alternatively the display showing active error codes 2 4 Indication of time fo...

Страница 21: ...ress LEFT BUTTON SW1 continuously for 2sec to exit from service menu F The display now goes back to normal operation showing the state of the leveller shelter or the door 3 1 2 Set Shelter type A The...

Страница 22: ...ton S8 OPEN DOOR S00 will be displayed for 2 sec and winter mode is selected Function to summer mode Shelter function disabled The Leveller in resting position door closed and the shelter switched off...

Страница 23: ...the control box in immediate proximity to the connection blocks In order to prevent the components from being destroyed by static electricity during installation or service work any staff coming into...

Отзывы: