27
MYDENS
COSMOGAS
5.16.4 - “Split 80/80PP” System (Type C43;
C53; C83): installation examples
In figure 5.17 two examples of installation are given:
- exhaust into chimney with collection of condensate inside
the boiler itself.
The horizontal part of the fumes exhaust side must be inclined
towards the boiler.
The intake must slope towards the outside to prevent rain
water entering.
- exhaust to the outside directly with the boiler pipes with
condensate collection inside the boiler itself.
The intake must slope towards the outside to prevent rain
water entering.
in figure 5.18 it is possible to see a separated type of fumes
exhaust, where fumes exhaust was realised with flexible hose
in polypropylene for piping of technical cells.
The condensate produced in the vertical pipe must all be
conveyed into the boiler.
The intake must slope towards the outside to prevent rain
water entering.
Figure 5.17 - Example of “80/80 PP System”
installation
Figure 5.18 - Example of “80/80 PP System” installation