020002.01.006
5 - INSTALLATION
5.8 - Mounting the appliance
Refer to figure 5.3:
1.- place the paper template, provided with the appliance,
against the wall;
2.- check that the template is square to the environment;
3.- mark the holes for the plugs and hydraulic fittings on the
wall;
4.- remove the paper template;
5.- make the holes “A” and introduce the wall plugs “B”;
6.- make the boiler hydraulic and gas connections;
7.- hang the boiler on the plugs “C”;
8.- make the hydraulic fittings.
5.9 - Condensate drain
There is a siphon inside the boiler for the evacuation of
condensate (see figure 3.1 detail “49”) and to prevent
combustion products from escaping, whose end
corresponds to the pipe “B” in figure 5.4. This termination
must be conveyed into an anti-odour siphon
(figure
5.7 detail “G”) to prevent bad odours returning into the
environment (the anti-odour siphon “G” is supplied on
request).
Open the tank “A” as indicated in figure 5.4 and fix it using
the screw “D”, connect the drain pipe “F” as indicated in
figure 5.5.
In particular, the condensate drain plant must be:
for room used for residential purposes and for office with
more than 10 users, it can be connected to the domestic
waste disposal plant by means of appropriate siphon with
disjunction capable of preventing the pressurisation of
the system (siphon prepared within boiler) and to prevent
the return of bad odours from the sewer (detail “G” in
figure 5.7). If the room used for office purposes has
less than 10 users, before connection with the domestic
waste drain, a condensate neutraliser is good practice
(see chapter 9 for the value of acidity of the condensate
and the quantities).
be performed with a pipe with internal diameter equal to
or greater than 13 mm;
be installed in a way to prevent the liquid from freezing;
therefore pay attention to any external passings. It is
prohibited to drain into gutters or drainpipes;
to slope continuously towards the drain point, avoid high
points, which could pressurise the pipe;
5.10 - Safety valve
The appliance is protected against overpressures by a
safety valve calibrated to 3 bar (see figure 3.1 detail “7”).
The safety valve drain (detail “C” in figure 5.4), along
with the condensate drain (detail “B” in figure 5.4) must
be conveyed to a pipe “F” (see figure 5.5) with minimum
internal diameter of 13 mm; the pipe “F” must be then taken
to the anti-odour siphon (detail “G” figure 5.7). This drain
with siphon is used to prevent overpressures if the valve
is opened and makes it possible for the user to check the
eventual intervention.
The pipe “F” in figure 5.5 is supplied as per standard along
with tank “A” in figure 5.4. The anti-odour siphon “G” in
figure 5.7 is provided on request.
ATTENTION !!! If not connected to the drain,
whenever the safety valve should intervene, it could
cause damage to persons, animals or objects.