85
After choosing desired plug-in and clicking
Ok
button the following window will appear
as shown on Fig. 7.3.
Fig. 7.3 SNMP Agent Settings Window
In “Agent” section you need to specify the IP address or name of the SNMP agent.
Default SNMP Node configuration values will appear, assuming the Agent is running on
a local PC or in Corinex device. If the user wants to use the SNMP Agent which is
running on a
Corinex Wireless to Powerline Router G
device, the name or IP address of
this device must be written in to the text field Agent
Address
. The default IP address of
the
Corinex Wireless to Powerline Router G
is
10.0.0.2
. The insertions for the fields:
Port, Read and Write community must be in accordance with the naming of the Agent’s
settings In “Connection” section you need to specify the Timeout and the number of
Retries for the SNMP communication. In “Node” section you need to specify a unique
name for the new SNMP node. Then, after inserting these names and number settings,
you must click on the
Add
button after clicking on this button, the new SNMP node will
be added as selected plug-in.