Xenus XSL User Guide
Quick Setup with CME 2
Copley Controls Corp.
95
5.8.2: Standard Digital Outputs
5.8.2.1
Click the
Digital Outputs
tab of the
Input/Output
screen.
Lo/Hi: Indicates current state of output.
Red light: output is active.
Grey light: output is not active.
5.8.2.2
Choose any of the following functions for any output. OUT4 is recommended for brake
function.
Output Function
Description
For More Information
Not Configured
No function assigned. Output
remains high.
Fault Active High
Output goes high when at least
one fault is detected.
Fault-Active Low
Output goes low when at least one
fault is detected.
Faults (p. 36).
Brake-Active High
Output goes high to activate the
brake.
Brake-Active Low
Output goes low to activate the
brake.
Brake Operation (p. 33).
PWM Sync Output
(OUT1 only)
The PWM synchronization output.
PWM Sync Input (p. 43)
and
PWM Sync Output (p. 44)
.
Custom-Active High
The output goes high when one or more of the triggering events are
detected.
To set the triggering events, see
Custom Digital Outputs (p. 96)
.
Custom-Active Low
The output goes low when one or more of the triggering events are
detected.
To set the triggering events, see
Custom Digital Outputs (p. 96)
.
Program Control High
Output state controlled by CVM or CAN program
Program Control Low
Output state controlled by CVM or CAN program