Quick Setup with CME 2
Xenus XSL User Guide
82
Copley Controls Corp.
5.3: Prerequisites
5.3.1: Hardware and Equipment
5.3.1.1
Verify that +24 Vdc power is OFF and AC power is OFF.
5.3.1.2
Verify wiring and connections.
Ensure the following connections are wired according to the guidelines in
Wiring (p. 59)
.
1
J8 "FDBCK" motor signals
2
J2 "U V W Earth" motor power
3
J7 "CNTRL" control signals
4
J4 "+24 Vdc, BRAKE" re24 Vdc (power OFF)
5
J5 "RS-232" PC serial link
6
J1 "L1 L2 L3 Earth" line power (power OFF)
5.3.1.3
Secure the motor:
1
Make sure motor is securely fastened.
2
Make sure that no load is connected to the motor.
5.3.1.4
Apply +24 Vdc to the amplifier’s J4 connection.
(Do NOT apply AC voltage to the amplifier at this point.)
Risk of unexpected or uncontrolled motion with CME 2 in CAN mode.
!
DANGER
CME 2 can be used while the amplifier is under CAN control. However, some
extreme changes made with CME 2 could cause unexpected or uncontrolled motion.
Failure to heed this warning can cause equipment damage, injury, or death.