Xenus XSL User Guide
Quick Setup with CME 2
Copley Controls Corp.
97
5.8.5: Fault Latching
5.8.5.1
Click
Configure Faults
(
) to open the
Fault Configuration
screen.
5.8.5.2
To make a fault condition latching, click to put a check mark next to the fault
description.
Risk of unexpected motion with non-latched faults.
!
DANGER
After the cause of a non-latched fault is corrected, the amplifier re-enables the PWM
output stage without operator intervention. In this case, motion may re-start
unexpectedly. Configure faults as latched unless a specific situation calls for non-
latched behavior. When using non-latched faults, be sure to safeguard against
unexpected motion.
Failure to heed this warning can cause equipment damage, injury, or death.
For more information on faults, see
Faults (p. 36)
.
5.8.5.3
To restore factory defaults if needed, click
Restore Defaults.
5.8.5.4
Click
OK
to save fault configuration settings to volatile memory and close the
Fault Configuration
screen
OR
click
Cancel
to restore to previous values and close the screen.
5.8.5.5
On the
Main
screen, click
Save to Flash
(
).