Regen Resistor Sizing and Configuration
Xenus XSL User Guide
158
Copley Controls Corp.
A.2: Configuring a Custom Regen Resistor
A.2.1: Regen Configuration Objective and Warning
Configure the amplifier to operate properly with the custom resistor.
Incorrect values may damage amplifier or external regen resistor.
!
WARNING
For the regen I
2
T algorithms to work correctly, the values entered in the following
steps must be correct. Damage to the external regen resistor may result from
incorrect values entered. Damage to the amplifier may result if an incorrect
resistance value is entered.
Failure to heed this warning can cause equipment damage.
A.2.2: Regen Configuration Instructions
A.2.2.1
On the
Main
screen, click
Configure Regen
(
) to open the
Regen
Resistor
screen.
A.2.2.2
Select
Custom Resistor
and then click
Configure
to open the
Custom Regen
Configuration
screen.
A.2.2.3
Enter a
Resistance
within the range described on the screen. Click
Next
for Step 2.