Signal
Pin
+24V Input
4
+24V to brakes
3
brake
2
+24V return
1
Signal
Pin
Motor Phase U
4
motor Phase V
3
motor Phase W
2
frame Ground
1
Signal
Pin
mains Input l3
5
frame Ground
4
Pe Ground
3
mains Input l2
2
mains Input l1
1
PIn
SIGnal
PIn
SIGnal
1
frame Gnd
6
STo-In1(+)
2
STo-In1(+)
7
STo-In1(-)
3
STo-In1(-)
8
STo-mute
4
STo-In2(+)
9
STo-Gnd
5
STo-In1(-)
J1
J3
J4
J5
J6
FEEDBACK
CONTROL
+24
+24
BRK
24V RTN
SAFETY
L1
L2
L3
U
V
W
BRAKE
MOTOR
POWER
Xenus
Plus
5 min
x10
x1
DEVICE ID
S1
S2
NETWORK
ERR
L/A
RUN
L/A
RS-232
A
B
AMP
J8
J7
OUT
IN
J2
Copley Controls, 20 Dan Road, Canton, MA 02021, USA
P/N 16-01436 Rev 01
Page 21 of 28
RoHS
Xenus
PLUS
Compact
CANopen
XPC
J1 maInS ConneCTIonS
J2 moTor ouTPuT
J3 +24 VdC & brake
W
ARNING: Hazardous voltages exist on
connections to J1, & J2 when power is
applied, and for up to 4 minutes
after power is removed
.
ISolaTed CIrCuIT
J4 SafeTy (STo)
connectors & sIgnals