For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the
installation procedure found on the website for your venting supplier.
For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed
using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and
outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to
the appliance fl ue collar which must be sealed using the black high temperature sealant Mill Pac. High
temperature sealant must be ordered separately.
When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the
following termination kits: wall terminal kit
GD-222
,
GD-222R
, or 1/12 to 7/12 pitch roof terminal kit
GD-110
,
8/12 to 12/12 roof terminal kit
GD-111
, fl at roof terminal kit
GD-112
or periscope kit
GD-201
(for wall
penetration below grade). With fl exible venting, in conjunction with the various terminations, use either the 5
foot (1.5m) vent kit
GD-220
or the 10 foot (3.1m) vent kit
GD-330
.
For optimum fl ame appearance and appliance performance, keep the vent length and number of
elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal
at least once a year to verify that it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components
must not be combined.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal
run is 20 feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of
vent connections is two horizontally or three vertically (excluding the appliance and the air
terminal connections) when using fl exible venting.
8.1C
Содержание CB30NTR
Страница 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Страница 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Страница 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Страница 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Страница 55: ...55 EN W415 1398 C 06 15 17 D ein stall the pre vio usly rem ove d sec urin g scr ews SIDE VIEW X5...
Страница 83: ......
Страница 84: ......