43
EN
W415-1398 / C / 06.15.17
Minimum clearance to combustible construction from appliance and vent surfaces:
Combustible Framing:
-
0" to stand-offs
-
1" (25mm) to bottom and sides of the vent pipe*
-
3" (76mm) to top of the vent pipe*
Combustible Finishing:
-
0" to rear
-
0" to front face top and sides
Top Exit
-
50 1/2" (1283mm) to combustible enclosure top from base of the appliance
-
54"
(1372mm) to ceiling from base of the appliance
Rear Exit
-
41 5/8" (1057mm) to combustible enclosure top from base of the appliance
-
54" (1372mm) to ceiling from base of the appliance
*
HORIZONTAL VENT SECTIONS:
A minimum of 1" (25mm) at the bottom and sides and 3" (76mm) at
the top of the vent pipe on all horizontal runs to combustibles is required. Use firestop spacer W010-1777
(supplied).
NOTE: The minimum clearances from the top of the horizontal vent pipe to combustible materials may
be reduced from 3"(76mm) to 1"(25mm) in those installations with a minimum 38" (965mm) vertical
vent rise made immediately off the fireplace collar.
*
VERTICAL VENT SECTIONS:
A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use firestop spacer W500-0096 (not supplied).
5.2
MINIMUM ENCLOSURE CLEARANCES
Содержание CB30NTR
Страница 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Страница 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Страница 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Страница 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Страница 55: ...55 EN W415 1398 C 06 15 17 D ein stall the pre vio usly rem ove d sec urin g scr ews SIDE VIEW X5...
Страница 83: ......
Страница 84: ......