31
EN
W415-1398 / C / 06.15.17
A. Apply a bead of caulking (not
supplied) around the corner edge of
the inside surface of
the fi restop assembly, fi t the fi restop assembly
to the hole and secure using the 4 screws
(supplied in your manual
baggie).
NOTE : Do not fi ll the air space
between the fi restop spacer and the exterior wall with any type of
insulating material (i.e., spray foam).
B. Once the vent pipe is installed in
its fi nal position, apply red
RTV silicone sealant (W573-0002) (not supplied) between the pipe and the
fi restop.
4.1.2 VERTICAL INSTALLATION
20.7D
This application occurs when venting through a roof. Installation kits for
various roof pitches are available from your authorized dealer /
distributor. See accessories to order specifi c kits required.
A.
Determine the air terminal location, cut and frame a square opening as illustrated in the ceiling
and the roof to provide the minimum 1" (25mm)
clearance between the vent pipe and any combustible material. Try to center the vent pipe location midway between two
joists to prevent having to cut them. Use a plumb bob to line up the center of the
UNDERSIDE OF FIRESTOP
openings. A vent pipe shield will prevent any materials such as
JOIST
insulation, from fi lling
up the 1" (25mm) air space around the pipe. Nail headers between the joist for extra support.
B.
Apply a bead of caulking (not supplied) to the framework or to the
Wolf Steel vent pipe shield plate or equivalent (in the case of a fi nished ceiling), and secure over the opening in the
ceiling. A fi restop must be placed
VENT PIPE
CAULKING
on the bottom of each framed opening in a roof or ceiling that the venting
SHIELD
system passes through. Apply a bead of caulking all around and place a
VENT
fi restop spacer
over the vent shield to restrict cold air from being drawn into the
PIPE
room or around the fi
replace. Ensure that both spacer and shield maintain the required
COLLAR
clearance to
combustibles. Once the vent pipe is installed in its fi nal position, apply
Mill Pac sealant (W573-0007) (not supplied) or red RTV silicone (W573-0002) (not
VENT
supplied) between the pipe and the fi restop assembly.
PIPE
C.
In the attic, slide the vent pipe collar down to cover up the open end of the shield
and
SHIELD
tighten. This will prevent any materials, such as insulation, from fi
lling up the 1" (25mm) air space around the pipe.
21.1B
Содержание CB30NTR
Страница 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Страница 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Страница 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Страница 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Страница 55: ...55 EN W415 1398 C 06 15 17 D ein stall the pre vio usly rem ove d sec urin g scr ews SIDE VIEW X5...
Страница 83: ......
Страница 84: ......