23
EN
W415-1398 / C / 06.15.17
= .03 (90 + 90 + 90 + 90 + 45 - 90) = 9.45 FT (2.9m)
H
T
=
H
R
+ H
O
= 5.5FT (1.7m) + 9.45FT (2.9m) = 14.95FT (4.6m)
H
T
+ V
T
= 14.95FT (4.6m) + 5.5FT (1.7m) = 20.45FT (6.2m)
Formula 1:
H
T
< 3.5V
T
3.5V
T
= 3.5FT (1.1m) x 5.5FT (1.7m) = 19.25FT (5.9m)
14.95 FT (4.6m) < 19.25 FT (5.9m)
Formula 2:
H
T
+ V
T
< 24.75 FT (7.5m)
20.45 FT (6.2m) < 24.75 FT (7.5m)
Since both formulas are met, this vent configuration is acceptable.
3.10 TOP AND REAR EXIT VERTICAL TERMINATION
(H
T
) < (V
T
)
Содержание CB30NTR