W415-1398 / C / 06.15.17
*MAXIMUM INLET PRESSURE NOT TO EXCEED 13”
-
Check if pilot can be lit by a match.
-
Check that the wire is connected to the push button igniter.
-
Check if the push button igniter needs tightening.
-
Replace the wire if the wire insulation is broken or frayed.
-
Replace the electrode if the ceramic insulator is cracked or
broken.
-
Replace the push button ignitor - Fill the tank.
-
Spark gap should be 0.150” (3.8mm) to 0.175” (4.5mm) from
the electrode tip and the pilot burner. To ensure proper
electrode location, tighten securing nut (fi nger tight plus 1/4
turn).
-
Check that the manual valve is turned on.
-
Check the pilot orifi ce for blockage.
-
Replace the valve.
-
Call the gas distributor.
-
Check pressure readings:
-
Inlet pressure can be checked by turning screw (A)
counterclockwise 2 or 3 turns and then placing pressure
gauge tubing over the test point. Gauge should read as
described on the chart below. Check with main burner is
operating on
‘HI’.
-
Outlet pressure can be checked the same as above using
screw (B). Gauge should read as described on the chart
below. Check that main burner is operating on ‘HI’.
-
AFTER TAKING PRESSURE READINGS, BE SURE TO
TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO
NOT OVER TORQUE.
-
Leak test with a soap and water solution.
Pressure
Natural Gas
(inches)
Natural Gas
(millibars)
Propane
(inches)
Propane
(millibars)
Inlet
*13"
(MIN. 4.5”)
17.4mb (MIN.
11.2mb)
13"
(MIN. 11")
32.4mb
(MIN. 27.4mb)
Outlet
3.5"
8.7mb
10"
24.9mb
Содержание CB30NTR
Страница 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Страница 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Страница 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Страница 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Страница 55: ...55 EN W415 1398 C 06 15 17 D ein stall the pre vio usly rem ove d sec urin g scr ews SIDE VIEW X5...
Страница 83: ......
Страница 84: ......