background image

1 | 

P a g e

 

 

 

 

Wood Insert: Ref B5.2 & B5.2 F

    

                                          

 

 

Performance: 

 

10kW heat output 

 

71.5% Efficiency 

 

Double 
combustion: Yes 

 

Consumption at 
normal rate 
3.96kg/h 

 

Average 
temperature of 
smoke: 300°c  

 

Carbon Monoxide 
0.1% 

 

Carbon Dioxide 
7.76% 

 

Distance from 
Combustible 
materials: 
50cm sides, 50cm 
back, 10cm base  

Characteristics: 

 

Weight 140kg 

 

Wood only 

 

Log length: up to 
50cm 

 

Flue φ 180mm 
from the top 

 

Front loading 

 

Dimensions: 
77Lx71.5Hx44D 
cm 

 

Dimensions:  

 

Содержание B5.2

Страница 1: ...mption at normal rate 3 96kg h Average temperature of smoke 300 c Carbon Monoxide 0 1 Carbon Dioxide 7 76 Distance from Combustible materials 50cm sides 50cm back 10cm base Characteristics Weight 140kg Wood only Log length up to 50cm Flue φ 180mm from the top Front loading Dimensions 77Lx71 5Hx44D cm Dimensions ...

Страница 2: ...and safety or installation regulations 1 Particulars for the electrical connection units with fans a Any electrical connection must conform to the local regulations b The electrical connection to the power cable of the unit should be done by means of an electrical junction box c If the heater cable is damaged in any way it should be replaced d The cable and junction box should be appropriately ins...

Страница 3: ... its full height If the unit is seated on a non flammable base it would only be necessary to insulate the sides and back of the cavity to their full height d If there is any material within the cavity construction which may be of a flammable nature it is recommended to build a new supporting framework which is in itself insulated to its full height e Under no circumstances must the actual unit its...

Страница 4: ...low for maintenance and access to the top of the unit Hot air diffusers a Diffusers with a cross sectional area of not less than 500cm must be situated not less than 30cm from the ceiling and these must not be obstructed One must also take care that where the diffusers allow hot air to circulate they cannot affect sensitive material such as moulded ceilings PVC polystyrene cornices etc 6 Ventilati...

Страница 5: ... the unit and with a cross sectional area of at least 200cm 1 4 of the cross section of the chimney minimum Fan assembly convection acceleration Nomenclature of electric parts No Qty Description Code No Qty Description Code 1 1 Thermostat bulb support LHS 147633152 7 2 Ventilation grid type 4000 107 2 1 Thermostat bulb support RHS 147633152 8 1 Resistor arcol hs50 820r 3 2 Thermostat junction 0000...

Страница 6: ...reached It can happen when the fans are off or on slow speed This is not a temperature regulation but a protection against over heating As a security measure for the protection of the motors should there be an electrical power failure one should reduce the combustion rate of the fire During normal operation the air that comes in at an average temperature of 18 C is expelled at a temperature of 150...

Страница 7: ...by making a fire on top of the grate Typically some newspaper dry kindling and a couple of small split logs would be used for the starter fire Light the newspaper close the door and open the air intake completely Once the fire is burning well it can be loaded Never use petrol or alcohol to start or increase the fire When lighting a new fire it is recommended to keep a bed of ash on the grid and th...

Страница 8: ...r a window and that the damper is open Let an installer check the draw of your chimney and to ensure that any flue or tubing is in good condition Insufficient heat or the fire is going out Put smaller pieces of wood on a good bed of coals Use drier wood As above have the chimney checked Low heat output with a substantial fire Check that the unit itself is in good condition Use bigger diameter logs...

Страница 9: ... the door closed One must always pay attention to the burning of your unit in order to get the best results from it Rather load your unit more often than loading it excessively After each loading the fire should initially burn at a high rate so that any condensing fumes can be rapidly eliminated at the start of the burn Using the unit on a very slow burn for long periods is not recommended especia...

Страница 10: ...on If the unit has fans it is important that the electrical supply to the unit is always on This is imperative as the fans will automatically come on as a protective measure when they get hot even if the two way switch on the unit is in the off position ...

Страница 11: ...ages Description 1 The top of the unit is delivered as per the picture 2 Put the spigot in place as shown Attach it with the two bolts supplied 3 Position the damper as shown Where the protrusion on the damper is facing upwards on the back RHS 4 Insert the damper as shown and keep it in this position for step 5 5 Insert the damper rod through the two holes through the front frame of the heater and...

Страница 12: ...TH M8x20 ZN black 1301145 1 Damper shaft 157243258 1 97mm external spigot 143123276 2 Lug 142303736 1 Ash tray 133163158 1 Outer convection box 229063158 1 Glass 000013158 1 Motor support 253763158 2 Flat seal 8x 1mm 6308 2 3m 8mm rope seal 061082 3m Glass clamp 120713152 1 Door latch bolt off centre 3075BC 1 Air circulation grid RHS 102463158 1 Air circulation grid LHS 102453158 1 Switch support ...

Страница 13: ...ect to correct installation use and maintenance of the unit Parts that are in direct contact with high temperatures and that could undergo distortions caused by wear and tear are guaranteed for 1 year This includes 1 Decorative panels side panels grates ...

Страница 14: ...nly break because of a mechanical shock while using or handling the appliance 2 Glass seals and ceramic rope seals are considered wear and tear items The following will invalidate any warranty 1 Damage caused by burning fuels other than those for which the unit is intended 2 Any defect or deterioration caused by a fall shock negligence or lack of supervision and maintenance 3 Deterioration of part...

Отзывы: