33
c)
Servo End Deflection Setting "EPA"
Using the servo end deflection setting "End Point Adjustment" you can precisely define the maximum size of servo
travel that is permitted. The servo end deflection function is typically used to protect servos from mechanically hitting
an obstacle when deflecting to the full extent. Foe each of the four control channels (CH1 - CH4), the EPA values can
be set individually.
The EPA values of all control channels are set to 100% ex works and should not be changed.
Setting the servo end deflection
Call the programming menu.
"REV" starts to flash in the display.
Push the buttons "UP" and "DOWN", until "EPA" flashes in the
display and you can call it with the button "SELECT".
The display shows the indication for control channel 1, with digit
"1" flashing. In addition to the control channel, the currently set
"EPA" value is displayed.
Use the buttons "UP" or "DOWN" to select the control chan-
nel 1 to 4 for which the "EPA" value is to be set or changed.
When the desired control channel is displayed, push the button
"SELECT". The percentage setting value now starts to flash.
You can use the buttons "UP" or "DOWN" now to set the per-
centage. The larger the value set, the farther will the servo be
deflected.
When the desired value is set, it must be confirmed and saved
with the button "SELECT".
The buttons "UP" and "DOWN" can then be used to call another
control channel for which you want to change the "EPA" value,
or you can leave the programming menu again by pushing both
buttons together.