4.3
Device protection
The device is equipped with the following functions which protect the device:
Overload
Automatic shutdown at an output voltage > 32 V DC.
Output protected up to 100 V (protection against reverse polarity)
Interlock DC output
Automatic switch-off with unplugged plug
Overload/undervoltage
Hiccup mode, see chapter 8.6
Energy recovery
Protected up to 50 V against energy recovery.
Excessive temperature
Automatic shutdown by internal temperature monitoring.
e.g. by exceeding the permissible ambient temperature and/or the maximum permissible
output power
4.4
Mechanical integration
Dimensions
See drawings
Weight
approx. 10.2 kg (without connecting cables)
Surface temperature
Heat sink surface temperature max. 70°C, depending on operating status
Nominal air gap
All given data refer to a nominal air gap of 10 mm between the lower edge of the pickup and
the ground surface.
Observing the installation instructions MV9100-0032 and MV9100-0037 for floor installation,
this results in an effective distance of 15 to 16 mm between the lower edge of the pickup and
the upper edge of the track line. Please refer to 8.3 regarding further relevant tolerances.